Рус Eng

Equipment of the EMC Test Center

Since 2000, the Test Center has been operating a 3-meter semi-anechoic shielded chamber by Lindgren-Rayproof with radio frequency absorbing material by TDK for testing equipment in the frequency range up to 18 GHz, for monitoring noise emissions in the frequency range 9 kHz to 40 GHz and testing stability in the range 26 MHz to 18 GHz at loading levels of up to 200 V/m: IEC 61000-4-3, IEC 61000-4-6 (GOST 30804.4.3-2013, GOST R 51317.4.6-99, IEC 61000-4-3, IEC 61000-4-6, GOST R 51320-99, GOST R 51318.11-2006, GOST 30805.14.1-2013, GOST 30805.22-2013, CISPR-11, CISPR-14-1, CISPR-22).

In December 2012 VNIIA in addition to the existing equipment put into operation a unique technological complex in Russia with a semi-anechoic shielded chamber (SASC) with a 10-meter test foundation, which allows comprehensive tests of large products in assembled form with evaluation of full-function algorithms of their work.

EMC Test Center is equipped with the most advanced new generations of special measurement equipment, which meets the requirements of national and international standards from the global leading suppliers in this area, such as: Schaffner-Chase EMC, Rohde & Schwarz, Amplifier Research, EMCO, Tektronix, EMTEST, EMC Partner, etc., in particular, "Profline 3000" automated test system by Schaffner-Chase EMC and shielded chamber by Lindgren-Rayproof for certification tests for conducted interference and conducted interference emission of Rosatom products and other imported industrial products to meet national standards GOST 30804.4.13-2013, GOST 30804.4.4-2013, GOST R 51317.4.5-99, GOST 30804.4.11-2013, GOST R 50648, GOST R 50649, GOST R 50652, GOST R 51317.4.12, GOST R 51317.4.13, GOST R 51317.4.14-2000, GOST R 51317.4.16, GOST R 51317.4.28-2000, GOST 30804.3.2-2013, GOST 30804.3.3-2013, and IEC 61000-4-2, -4, -5, -8, -9, -10, -11, -12.-13, -14, -16, -28, 61000-3-2, -3 standards

  SASC-3 in EMC Test Center by Lindgren-Rayproof, 2000. SASC-10, by TDK, 2012, 2000.
Dimensions (L × W × H) (m) 8,5×6,1×5,5 13×21×9
Distance between transceiver antenna and turntable center (m) 3 10
Dimensions of chamber door (W × H) (m) 1,6×1,9 3,6×3,6
Turntable diameter (m) 2,0 4,0
Turntable lifting capacity (kg) 500 3 000
Shielding range от 10 kHz до 6 GHz от 10 kHz до 40 GHz
Loading with radio-frequency field до 2 GHz, 200 V/m до 18 GHz, 200 V/m

Rohde & Schwarz

  • signal generators: SMA-01 (9 kHz-1 GHz), MY-02 (9 kHz-2 GHz) SMP04 (2 GHz to 40 GHz);
  • measuring receivers: ESI-40 (20 Hz - 40.0 GHz) EB200 (compact, transportable);
  • power meters: URV-5, NRVD (9 kHz - 2 GHz);
  • industrial PC (Interference-proof) РЗР7.

Amplifier Research

  • broadband amplifiers: 100W100M1 (100 W, 80 MHz - 1000 MHz), 250A250 (250 W, 10 kHz - 250 MHz), 500A100 (500 W, 10 kHz - 100 MHz), 500W1000M5 (500 W, 80 MHz - 1000 MHz), 1000L (1200 W, 10 kHz - 220 MHz), 200TG2 (200 W, 1 GHz - 2 GHz);
  • systems for measuring high-frequency electromagnetic fields: FP 4000 (10 kHz - 1 GHz), FP 4080 (80 MHz - 40 GHz);
  • powerful broadband antenna AT 1080 (2 kW, 80 MHz - 1 GHz).

EMCO

  • antennas for measuring E-and H-fields: 3505, 6505, 3121С;
  • set of horn antennas: 3115, 3116, 3161-01, 3161-02, 3161-03.

Tektronix

  • digital oscilloscopes: TDS 784, THS730A, TDS 5400, TDS 420.

Schaffner-Chase EMC

  • test system on noise emission Emipack (9 kHz - 2 GHz);
  • broadband antennas: CBL 6140, (25MHz - 2GHz), CBL6112C;
  • software for testing the stability and emissions: CIS 9942, CES 9985 EMI;
  • multi-function testing system Profline 3000.

Transportable testing facility for field measurements of electromagnetic environment and testing for noise immunity